Back to home page

EIC code displayed by LXR

 
 

    


Warning, /geant4/examples/extended/medical/dna/UHDR/beam.in is written in an unsupported language. File is not indexed.

0001 #/run/numberOfThreads 10
0002 /process/dna/e-SolvationSubType Meesungnoen2002
0003 #/process/dna/e-SolvationSubType Ritchie1994
0004 #/process/dna/e-SolvationSubType Terrisol1990
0005 
0006 /process/chem/TimeStepModel IRT_syn
0007 
0008 # Set the simulation volume (half Side Length)
0009 #/UHDR/env/volume 0.8 um # for UHDR
0010 /UHDR/env/volume 1.6 um # for CONV
0011 
0012 /UHDR/Detector/PBC true
0013 
0014 # time structure
0015 /UHDR/pulse/pulseOn true
0016 # push structure file
0017 /UHDR/pulse/pulseFile 1.4us
0018 
0019 # pulse structure
0020 /UHDR/pulse/multiPulse true
0021 /UHDR/pulse/pulsePeriod 10 ms
0022 /UHDR/pulse/numberOfPulse 2
0023 #/UHDR/pulse/pulseInHisto pulseHisto.txt
0024 
0025 /run/initialize
0026 
0027 # pH and Scavenger
0028 /UHDR/env/pH 5.5
0029 
0030 # Oxygen concentration
0031 /UHDR/env/scavenger O2 21 %
0032 
0033 /chem/reaction/print
0034 
0035 #/run/verbose 1
0036 /tracking/verbose 0
0037 /scheduler/verbose 1
0038 /scheduler/endTime 10 s
0039 
0040 # set false if many beamOn in medium
0041 /scheduler/ResetScavengerForEachBeamOn true
0042 
0043 /scorer/Gvalues/nOfTimeBins 80
0044 
0045 /run/printProgress 10
0046 
0047 /scorer/Dose/cutoff 0.1 Gy
0048 /UHDR/source/particle e-
0049 /UHDR/source/energy 0.999 MeV
0050 /run/beamOn 2