Back to home page

EIC code displayed by LXR

 
 

    


Warning, /geant4/examples/extended/medical/dna/microyz/microyz.in is written in an unsupported language. File is not indexed.

0001 # MT mode
0002 /run/numberOfThreads 8
0003 #
0004 # Verbosity
0005 /tracking/verbose 0
0006 #
0007 # Physics
0008 #/microyz/phys/addPhysics  liv
0009 #/microyz/phys/addPhysics  pene
0010 /microyz/phys/addPhysics  dna_opt2
0011 #/microyz/phys/addPhysics  dna_opt4
0012 #/microyz/phys/addPhysics  dna_opt6
0013 #
0014 # Tracking cut
0015 /microyz/det/setTrackingCut 11 eV
0016 #
0017 # Settings for Geant4 (condensed history) only
0018 #/run/setCut 1 nm
0019 #/cuts/setLowEdge 100 eV
0020 #/process/em/lowestElectronEnergy 100 eV
0021 #/microyz/det/setMaxStepSize 1 nm
0022 #
0023 # Sphere radius
0024 /microyz/det/Radius 2 nm
0025 #
0026 /run/initialize
0027 #
0028 # Activation of atomic deexcitation
0029 /process/em/fluo true
0030 /process/em/auger true
0031 /process/em/augerCascade true
0032 /process/em/pixe true
0033 /process/em/deexcitationIgnoreCut true
0034 #
0035 # Incident particle type
0036 /gun/particle e-
0037 #
0038 # Incident particle energy
0039 /gun/energy 1 keV
0040 #
0041 # Display run progress
0042 /run/printProgress 100
0043 #
0044 # Inactivation of some Physics processes if needed (e.g. for dna_opt2)
0045 # (For Geant4-DNA only)
0046 /process/inactivate e-_G4DNAVibExcitation