Back to home page

EIC code displayed by LXR

 
 

    


Warning, /geant4/examples/extended/electromagnetic/TestEm3/TestEm3.in is written in an unsupported language. File is not indexed.

0001 #
0002 # Macro file for "exampleN03.cc"
0003 #
0004 # Lead-liquidArgon 50 layers; electron 1 GeV
0005 #
0006 /control/verbose 2
0007 /control/cout/ignoreThreadsExcept 0
0008 /run/verbose 1
0009 #
0010 /testem/phys/addPhysics  emstandard_opt0
0011 #
0012 /process/em/verbose 1
0013 /process/msc/Skin 1
0014 /run/initialize
0015 #
0016 /gun/particle e-
0017 /gun/energy 1 GeV
0018 #
0019 ###/analysis/setFileName testem3
0020 ###/analysis/h1/set 1 100 700. 1000. MeV        #edep in absor1
0021 ###/analysis/h1/set 2 100   0.  300. MeV        #edep in absor2
0022 ###/analysis/h1/set 11 52   0.   52.  none      #long. profile in absor1
0023 ###/analysis/h1/set 12 52   0.   52.  none      #long. profile in absor2
0024 ###/analysis/h1/set 21 102  0.   102. none      #energy flow
0025 ###/analysis/h1/set 22 102  0.   102. none      #lateral energy leakage
0026 #
0027 /run/printProgress 50
0028 /run/beamOn 100
0029 #
0030 /process/em/setSecBiasing eIoni World 0.3 2 MeV
0031 /process/em/setSecBiasing eBrem World 0.2 1 MeV
0032 /run/physicsModified
0033 /run/beamOn 100
0034 #