Back to home page

EIC code displayed by LXR

 
 

    


File indexing completed on 2025-01-31 09:21:58

0001 //
0002 // ********************************************************************
0003 // * License and Disclaimer                                           *
0004 // *                                                                  *
0005 // * The  Geant4 software  is  copyright of the Copyright Holders  of *
0006 // * the Geant4 Collaboration.  It is provided  under  the terms  and *
0007 // * conditions of the Geant4 Software License,  included in the file *
0008 // * LICENSE and available at  http://cern.ch/geant4/license .  These *
0009 // * include a list of copyright holders.                             *
0010 // *                                                                  *
0011 // * Neither the authors of this software system, nor their employing *
0012 // * institutes,nor the agencies providing financial support for this *
0013 // * work  make  any representation or  warranty, express or implied, *
0014 // * regarding  this  software system or assume any liability for its *
0015 // * use.  Please see the license in the file  LICENSE  and URL above *
0016 // * for the full disclaimer and the limitation of liability.         *
0017 // *                                                                  *
0018 // * This  code  implementation is the result of  the  scientific and *
0019 // * technical work of the GEANT4 collaboration.                      *
0020 // * By using,  copying,  modifying or  distributing the software (or *
0021 // * any work based  on the software)  you  agree  to acknowledge its *
0022 // * use  in  resulting  scientific  publications,  and indicate your *
0023 // * acceptance of all terms of the Geant4 Software license.          *
0024 // ********************************************************************
0025 
0026 //GEANT4 - Depth-of-Interaction enabled Positron emission tomography (PET) advanced example 
0027 
0028 //Authors and contributors
0029 
0030 // Author list to be updated, with names of co-authors and contributors from National Institute of Radiological Sciences (NIRS)
0031 
0032 // Abdella M. Ahmed (1, 2), Andrew Chacon (1, 2), Harley Rutherford (1, 2),
0033 // Hideaki Tashima (3), Go Akamatsu (3), Akram Mohammadi (3), Eiji Yoshida (3), Taiga Yamaya (3)
0034 // Susanna Guatelli (2), and Mitra Safavi-Naeini (1, 2)
0035 
0036 // (1) Australian Nuclear Science and Technology Organisation, Australia
0037 // (2) University of Wollongong, Australia
0038 // (3) National Institute of Radiological Sciences, Japan
0039 
0040 //The header file consists of specification if the scanner geometry
0041 
0042 //Number of crystals (scintillators) in the DOI (x), tangential (y) and axial (z) direction. 
0043 #define numberOfCrystal_DOI 4
0044 #define numberOfCrystal_tangential 16
0045 #define numberOfCrystal_axial 16
0046 
0047 //size of the crystals in the DOI (x), tangential (y) and axial (z) direction. 
0048 #define sizeOfCrystal_DOI 7.5*mm
0049 #define sizeOfCrystal_tangential 2.8*mm
0050 #define sizeOfCrystal_axial 2.8*mm
0051 
0052 //Inter crystal gap between crystals. 
0053 #define crystalGap_DOI 0.0*mm
0054 #define crystalGap_tangential 0.08*mm
0055 #define crystalGap_axial 0.08*mm
0056 
0057 
0058 
0059 //Define Aluminum thickness cover for the detector
0060 #define AluminumCoverThickness 0.3 * mm
0061 
0062 //Number of PET detectors per ring
0063 #define numberOfDetector_perRing 40
0064 
0065 //Number of rings in the PET system 
0066 #define numberOfRings 4
0067 
0068 //Radius of the PET system. Note that the radius is defined between to opposing sensitive detectors (It does not include detector block cover).
0069 #define scannerRadius 330 * mm
0070 
0071 //Gap between two adjacent rings. There are three gaps in four ring PET system
0072 #define ringGap 10.4 * mm