0001 # Example doiPET History
0002
0003 See `CONTRIBUTING.rst` for details of **required** info/format for each entry,
0004 which **must** added in reverse chronological order (newest at the top). It must **not**
0005 be used as a substitute for writing good git commit messages!
0006
0007 ## 2023-11-15 I. Hrivnacova (doiPET-V11-01-01)
0008 - Updated vis.mac:
0009 - Changed "/vis/open XYZ [600x600-0+0]" to "/vis/open" to allow run-time choices
0010 and simplified comments.
0011
0012 ## 2023-11-10 Alberto Ribon (doiPET-V11-01-00)
0013 - In all macro files, introduced the UI command
0014 '/process/had/rdm/thresholdForVeryLongDecayTime 1.0e+60 year'
0015 to allow all radioactive decays (including the very long ones).
0016 This is necessary since G4 11.2, being 1 year the default time
0017 threshold above which the decays are ignored.
0018
0019 ## 2022-09-08 Susanna Guatelli (doiPET-V11-00-01)
0020 - Ranecu engine removed, default engine used now
0021
0022 ## 2021-12-10 Ben Morgan (doiPET-V11-00-00)
0023 - Change to new Markdown History format
0024
0025 ---
0026
0027 # History entries prior to 11.0
0028
0029 14.11.2021 - G. Cosmo;doiPET-V10-07-03
0030 - Fixed compilation warnings for unused private variables in
0031 doiPETDetectorConstruction and doiPETEventAction. Removed tabs.
0032
0033 16.10.2021 - S. Guatelli;doiPET-V10-07-02
0034 - Migration to the G4RunManagerFactory
0035 - Analysis now done with G4Analysis (no dependency towards external ROOT libraries)
0036 - Link to reference data and analysis scripts provided to
0037 let users compare simulatilesion results to reference data
0038 - Some controls to prepare DOI-look-up table is added.
0039 If DOI look-up table is provided as a file, then it will use it.
0040 If look-up table is not provided, the program will prepare the look-up table
0041 based on the information provided by the user (number of crystals, etc).
0042 - In performing Anger Logic calculation, the interaction position is mapped to the center
0043 of the crystal before 2D position error is added to model photomultiplier tube (PMT) error.
0044 - An analysis C++ program is provided to calculate the sensitivity of the scanner for a line source.
0045
0046 07.10.2021 - I. Hrivnacova (doiPET-V10-07-01)
0047 Removed unused include of g4root.hh
0048
0049 24.05.2021 - B. Morgan (doiPET-V10-07-00)
0050 Bump required CMake version range to 3.12...3.20, matching core Geant4
0051
0052 29.12.2020 - J.Allison; doiPET-V10-07-00
0053 Replace deprecated G4VisAttributes::Invisible by
0054 G4VisAttributes::GetInvisible().
0055
0056 02.11.2020 - B.Morgan; doiPET-V10-06-00
0057 Support same CMake version range as core Geant4
0058
0059 29.08.2019 - S. Guatelli;doiPET-V10-05-01
0060 G4VIS_USE and G4_UI removed
0061
0062 17.12.2018 - G. Cosmo;doiPET-V10-05-00
0063 Fixed compilation warnings on clang for unused data members in
0064 doiPETDetectorConstruction and doiPETEventAction classes.
0065
0066 25.10.2018 - S. Guatelli;doiPET-V10-04-00
0067 PET example introduced for the first time
0068